Krohne at a glance
Krohne is privately-held, family-owned, and the most product-distinctive of the European flow majors. Where most competitors cover every technology with a similar architecture, Krohne tends to ship a deliberately different design in each technology — and that design is often the reason to specify them.
Three obvious examples:
- OPTIMASS 6400 is the only major-vendor production Coriolis with a single straight measuring tube. No bends, no traps, no pressure drop above an equivalent straight pipe.
- WATERFLUX 3070 is the only widely-deployed magmeter with a rectangular cross-section primary — it removes nearly all upstream straight-run requirement and runs on internal batteries for up to 15 years (no mains needed at the bury point).
- ALTOSONIC V12 is the 12-path ultrasonic that has become the de-facto standard for LNG custody transfer and cryogenic hydrocarbon transfer.
Coriolis — OPTIMASS
- OPTIMASS 1400 — twin-tube workhorse, ±0.1% of rate liquid. The Krohne entry to general-process Coriolis.
- OPTIMASS 2400 — twin-tube custody-class, ±0.05% of rate liquid, OIML R117 / MID approved.
- OPTIMASS 6400 — single straight tube, advanced active-mass-compensation algorithm. The choice for hygienic CIP/SIP (no dead leg), high-viscosity duty, and any application where the bent-tube pressure drop or entrapment behaviour of conventional Coriolis is a problem.
- OPTIMASS 7400 — single straight tube, even larger line sizes; the typical choice for LPG, NGL custody transfer.
Electromagnetic — OPTIFLUX / WATERFLUX
- OPTIFLUX 1000 / 2000 / 4000 / 5000 — process magmeters in increasing duty / accuracy class. OPTIFLUX 5000 is the high-accuracy ±0.15% of rate variant.
- WATERFLUX 3070 — battery-powered water-utility revenue magmeter. Rectangular cross-section, near-zero upstream straight run, 15-year battery life, MID R49 / OIML R49.
- WATERFLUX 3300 — mains-powered version of the same architecture for higher-frequency logging duty.
Ultrasonic — ALTOSONIC
- ALTOSONIC V12 — 12-path ultrasonic, the reference custody-transfer meter for LNG, cryogenic hydrocarbons and large-line liquid hydrocarbons. ±0.15% of reading uncertainty after wet calibration.
- ALTOSONIC 5 — 5-path; the cost-effective alternative for non-custody large-line liquids.
- OPTISONIC 3400 / 6400 — clamp-on and inline ultrasonic for general liquid duty.
When InstruSelect promotes Krohne
The selector promotes Krohne strongly when:
- Coriolis with zero pressure drop and no bends is required (CIP / SIP / sterile services, viscous hydrocarbons, high-shear-sensitive media).
- Magnetic flow on a water utility trunk main where upstream straight run is unavailable.
- Custody LNG, cryogenic hydrocarbon, or large-line liquid hydrocarbon transfer — V12 is the reference.
- The site is in mainland Europe — Krohne service density in DACH, Benelux and the Nordics is unrivalled.
For high-volume gas custody transfer the typical alternative recommendation is Daniel 3415 or Emerson; for hygienic Coriolis the comparison is usually OPTIMASS 6400 vs Promass H — see the Coriolis comparison.
Datasheet sources
Curated from public Krohne Technical Datasheets (TDs) and Installation & Operating Instructions. Verify the live datasheet for any procurement decision.